10 PCE FDA CERTIFIED VERICHECK URINARY MULTI DRUG TEST
FDA Certified Vericheck Multi Drug Urinary Test – 10 Units
Detects 14 Drug Types - Crosschecks Adulterants - ISO 13485
Retail & Wholesale Orders - Minimum Order: 1 x Box / 10 Tests
Price Includes TO DOOR Courier Delivery Australia-Wide
All Shipments Issued With Tracking Number
Versatile
Configure your device with up to 6 specimen validity tests (adulterants)
Custom configures your cup or dip device with 1-14 different drugs and adulterants simultaneously.
Easy-to-use Cup Device
This test has been designed so that it requires no training or special understanding to use. Simply have the donor void directly into the collection cup and peel back the privacy label to reveal the results 5 minutes later.
Screening & Confirmatory Testing
This is a screening test device and does not provide a definitive test result. Laboratory confirmatory testing is recommended to confirm any non-negative test result.
Adulterant testing is used to confirm the validity of the specimen by checking 6 different parameters.
Cups and dips can be configured with the below adulterant test configurations:
SVT3A – 3-panel SVT strip CR SG PH
SVT3B – 3-panel SVT strip NI OX GL
SVT3C – 3-panel SVT strip CR PH OX
SVT6 – 6-panel SVT strip CR SG PH NI OX GL
Creatinine (CR)
Tests for sample dilution. In this assay, creatinine reacts with a creatinine indicator in an alkaline condition to form a purplish-brown colour complex. The concentration of creatinine is directly proportional to the colour intensity of the test pad.
Specific Gravity (SG)
Tests for sample dilution. Tests for sample dilution. The normal range is from 1.003 to 1.030. Values outside this range may be the result of specimen dilution or adulteration.
Oxidants (OX)
Tests for oxidants. This adulterant, sold under the brand name UrineLuck produces oxidants that should not be present in urine and may indicate that the sample has been adulterated.
pH (PH)
Tests for the presence of acidic or alkaline adulterant. This test is based on the well-known double pH indicator method that gives distinguishable colours over a wide pH range.
Nitrites (NI)
Tests for nitrites. Commercial adulterants such as Klear and Whizzies will cause a positive result for nitrites. These products work by oxidizing the major cannabinoid metabolite THC-COOH.Normal urine specimens should contain no trace of nitrites and positive results for nitrites usually indicate the presence of an adulterant.
Glutaraldehyde (GL)
This tests the presence of exogenous aldehyde. Adulterants such as UrinAid and Clear Choice contain glutaraldehyde which could cause a false negative result by disrupting the enzyme used in some immunoassays.
For Large Wholesale & Customised orders please contact OTTOP Office directly as prices vary considerably depending on order quantity.
All products are supported with Manufacturers Quality Assurance Guarantee & Product Warranty. Please ensure you have read our Purchasing & Refunds Policy prior to purchase.
Price Includes To Door Delivery
All Orders Issued With Tracking Number
Delivery Time: Approx. 6-10 days
Vericheck Test Configuration Details
Adulterant testing is used to confirm the validity of the specimen by checking 6 different parameters.Cups and dips can be configured with the below adulterant test configurations:
SVT3A – 3-panel SVT strip CR SG PH
SVT3B – 3-panel SVT strip NI OX GL
SVT3C – 3-panel SVT strip CR PH OX
SVT6 – 6-panel SVT strip CR SG PH NI OX GLCreatinine (CR)
Tests for sample dilution.In this assay, creatinine reacts with a creatinine indicator in an alkaline condition to form a purplish-brown colour complex. The concentration of creatinine is directly proportional to the colour intensity of the test pad.Specific Gravity (SG)
Tests for sample dilution.Tests for sample dilution.The normal range is from 1.003 to 1.030. Values outside this range may be the result of specimen dilution or adulteration.Oxidants (OX)
Tests for oxidants.This adulterant, sold under the brand name UrineLuck produces oxidants that should not be present in urine and may indicate that the sample has been adulterated.pH (PH)
Tests for the presence of acidic or alkaline adulterant.This test is based on the well-known double pH indicator method that gives distinguishable colors over a wide pH range.Nitrites (NI)
Tests for nitrites.Commercial adulterants such as Klear and Whizzies will cause a positive result for nitrites. These products work by oxidizing the major cannabinoid metabolite THC-COOH.Normal urine specimens should contain no trace of nitrites and positive results for nitrites usually indicate the presence of an adulterant.Glutaraldehyde (GL)
This test tests the presence of exogenous aldehyhe.Adulterants such as UrinAid and Clear Choice contain glutaraldehyde which could cause a false negative result by disrupting the enzyme used in some immunoassays.Purchasing & Returns Policy
Please refer to OTTOP "Purchasing & Returns Policy" Tab for full details